Studies On The Status Of Light Beam Diaphragms In Calabar: Effects And Implications On Radiation Protection

Main Article Content

N. O. Egbe
N. O. Chiaghanam
D. E. Bassey
E. E. Eshiet

Abstract

The status of Light Beam diaphragms (LDBs) in Calabar, Cross River State were studied using a quality assurance test method to check the beam alignment and collimator accuracy of x-ray equipment in diagnostic centers in Calabar. Results showed an increase in misalignment of the x-ray field and light field with an increase in the light field. The greatest misalignments were 7.9% and 5.6%along the cassette and across the cassette respectively. On the other hand, the least misalignments across and along the cassettes were 0.3% and 1.1% respectively. This indicates an unacceptable status of LBDs in Calabar, and the implication of this in image quality and radiation protection is noted as an undesirable development as it evidently contributes an unwelcome quantity to the radiation dose to the patient population.

Downloads

Download data is not yet available.

Article Details

Section

Original Article

How to Cite

Egbe, N. O., Chiaghanam, N. O., Bassey, D. E., & Eshiet, E. E. (2025). Studies On The Status Of Light Beam Diaphragms In Calabar: Effects And Implications On Radiation Protection. West African Journal of Radiology, 10(1), 34-42. https://doi.org/10.82235/wajr.vol10no1.136

References

1. Agwu KK. Radiation Practices in Radiodiagnosis in Nigeria. West African Journal of Radiology. 1992; 2 (1): 40 45.

2. Bryan GJ. Diagnostic Radiography. 3rd ed. London, Churchill Livingstone. 1979; 398p.

3. Carter P, Paterson A, Thornton M, Hyatt A, Milne A, Pirrie J. The X-ray Tube In: Chesney's equipment for Student Radiographers. 4th Ed. London. Blackwell Science. 2003; 315p.

4. Carrol QB. Field size Limitation In: Fusch's Principles of radiographic exposure, processing and quality control. 3rd Ed. Charles C. Thomas,

1985; pp. 124 129.

5. Chesney MO, Chesney DN. X-ray Equipment for Student Radiographers. 1st Ed. Blackwell Science. 1971; 522p.

6. Coulam CM, Erikson JJ, Rollo FD, James AE. The Physical Basis of Medical Imaging. 10th ed. New York, Appleton Century Crofts. 1985; 354p

7. Environmental Protection Agency EPA (1975): radiation, www.epa.gov/radiation.

8. Ikamaise VC, Osuagwu CN, Bassey DE, Egbe NO, Chiaghanam NO, Eduwem DU, Inah GB. Assessment of Chest radiographs for Quality

assurance and radiation protection. West African Journal of Radiology. (2000); 7 (1): 18 25.

9. Lloyd PJ. Accessory Equipment In: Quality Assurance workbook for radiographers and radiological Technologists. 1st Ed. Geneva, World

Health Organization. 2001; Pp. 29-44.

10. Yarmonenko SP. Direct and Indirect effects of Ionizing Radiation In: Radiobiology of Humans and Animals. 1st Ed. Moscow, Mir Publishers, 1988; pp. 45 50.